Manual J · single-family
A 1,286 sq ft home in the Chicago climate, with design temperatures on page one, window values from the plans and a load for every one of its 11 rooms.
- 1,286sq ft
- 11rooms calculated
- 3.14tons cooling
Real projects · client details removed
Eighteen complete reports we delivered for permit, shown exactly as the plan reviewer sees them. Open any PDF to check the format, the inputs and the pages your building department will ask for.
Send your plansA 1,286 sq ft home in the Chicago climate, with design temperatures on page one, window values from the plans and a load for every one of its 11 rooms.
20 pages · Elite Rhvac, ACCA Manual J 8th Ed.
View the full report (PDF) →A 2,850 sq ft Texas home on two systems. Manual J sizes every room, Manual S matches each unit to its load with the AHRI reference, Manual D sizes every runout and trunk.
Elite Rhvac · Manual J, S and D
View the full report (PDF) →A 15-unit building delivered as one permit package. Every apartment has its own room-by-room Manual J, duct sizes and equipment line, with the altitude correction applied.
Elite Rhvac · 4,843 ft altitude factor 0.837
View the full report (PDF) →A 3,837 sq ft restaurant build-out on two air handlers. Seating, kitchen equipment, lighting and outdoor air are entered for all 12 spaces, with the ASHRAE/ACCA Standard 183 form included.
Wrightsoft Right-Suite Universal 2026 · ACCA Manual N
View the full report (PDF) →A 5,687 sq ft new home with a full basement in climate zone 5A. One basement wall was over its U-factor limit and the whole-envelope trade-off still passes, with the new 2024 energy credits documented.
REScheck-Web, U.S. DOE
View the full report (PDF) →A 1,825 sq ft restaurant alteration with envelope, interior lighting and mechanical certificates, plus the full inspection checklist the reviewer and field inspector work from.
COMcheck-Web, 2021 IECC
View the full report (PDF) →A 1,955 sq ft new home in climate zone 2 with three heat pumps: R405 form, input summary, EPL display card, mandatory requirements and test report forms.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 4,229 sq ft new home in climate zone 1 with mixed wall assemblies, two ceiling types and four systems, each zone modelled on its own.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 4,675 sq ft new home with 1,692 sq ft of glass, offset by deep overhangs, low-SHGC windows and three high-SEER2 heat pumps.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 267 sq ft one-bedroom unit where a single 35 SEER2 ductless mini-split does most of the work.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 1,721 sq ft new home in climate zone 1. Two 25 SEER2 ductless heat pumps cut the modelled loads to less than half the reference home's.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 274 sq ft conditioned addition served by its own ductless mini-split, modelled on Form R405-2023.
Wrightsoft Right-Energy Florida 2023
View the full report (PDF) →A 384 sq ft home in climate zone 8 getting a new ductless heat pump. The CF1R shows the altered home beating the 2025 standard design, with the ECC field checks listed.
CBECC 2025 · CF1R-PRF-01-E
View the full report (PDF) →A 569 sq ft all-electric home in climate zone 12. Overhangs, a 20 SEER2 ductless heat pump and low-SHGC windows beat the 2025 standard, with no ECC field testing required.
CBECC 2025 · CF1R-PRF-01-E
View the full report (PDF) →A 1,249 sq ft three-bedroom home in climate zone 3. A 24 SEER2 heat pump, a tankless water heater, R-44 ceiling and an HRV carry it past the 2025 standard design.
CBECC 2025 · CF1R-PRF-01-E
View the full report (PDF) →A 1,130 sq ft restaurant tenant space on the nonresidential performance method. New 192 W lighting carries the space past the 2025 standard, with every installation and acceptance form listed.
CBECC 2025 · NRCC-PRF-E
View the full report (PDF) →A 2,929 sq ft outpatient clinic converted to fully conditioned space. WSEC lighting and mechanical compliance summaries on the state's own forms, space by space.
2021 WSEC commercial forms
View the full report (PDF) →A 1,549 sq ft new single-family home on the Total UA path. Better walls and floors pay for glazing above 15% of floor area, and the heat pump, HRV and heat pump water heater earn all 8 required credits.
WSU Code Compliance Calculator · 2021 WSEC
View the full report (PDF) →Across the six Florida R405 samples, every home passed the performance path, landing 6% to 52% under the code reference home. The four California Title 24 samples beat the 2025 standard design by 8.6% to 10.0%, and the Washington WSEC home came in 3% under the baseline envelope UA. The biggest margins came from high-SEER2 ductless heat pumps on small conditioned spaces.
| Sample | Location | Size | Result |
|---|---|---|---|
| K · R405 | North Palm Beach, FL | 1,721 sq ft | 52% under baseline |
| J · R405 | Orlando, FL | 267 sq ft | 43% under baseline |
| M · R405 addition | Windermere, FL | 274 sq ft | 38% under baseline |
| H · R405 | Palm Beach Gardens, FL | 4,229 sq ft | 13% under baseline |
| D · R405 | Ocala, FL | 1,955 sq ft | 6% under baseline |
| I · R405 | St. Petersburg, FL | 4,675 sq ft | 6% under baseline |
| P · Title 24 | Oakland, CA | 1,249 sq ft | 10.0% better than standard |
| O · Title 24 | Orangevale, CA | 569 sq ft | 8.9% better than standard |
| N · Title 24 | Anaheim, CA | 384 sq ft | 8.6% better than standard |
| S · WSEC | Seattle area, WA | 1,549 sq ft | Envelope UA 3% under baseline |
Send your plans and we will tell you which reports your AHJ needs, plus a quote, within 4 hours. Free.