A Manual J that gets bounced costs you days: the permit sits, the homeowner calls, and the crew waits. Most rejections have nothing to do with the math. They come from missing or mismatched details a plan reviewer can spot in minutes.
Run your report through these 10 checks before you submit. It's the same list we use on every load calc we send out.
The 10 things plan reviewers check
- Design temperatures. The outdoor summer and winter design temperatures are printed for the project's actual location.
- Room-by-room loads. The report shows a load for every room, not one whole-house number.
- ACCA-approved software. The calc comes from ACCA-approved software. Manufacturer sizing calculators usually aren't accepted.
- Insulation matches the plans. Wall, attic, floor and slab-edge R-values in the report match the construction drawings.
- Windows match the plans. U-factor, SHGC, area and orientation for each window match the window schedule.
- Realistic infiltration and duct location. Air leakage and where the ducts run (attic, conditioned space, crawlspace) reflect the real house.
- Equipment fits the load. The selected equipment is sized within Manual S limits. Florida, for example, allows no extra capacity for "future expansion".
- AHRI match number. The AHRI reference number for the matched system is on the cut sheet.
- Manual D when ducts change. If ducts are new or altered, a Manual D duct design is attached.
- Names and addresses match. The name, address and code edition match the permit application exactly.
Not sure your report passes?
Send your plans and we'll tell you which reports your AHJ needs, plus a quote, within 4 hours. Free.
Need the calc itself? See our Manual J load calculations, or read why Manual J reports get rejected.