Florida runs its own residential energy code framework under the Florida Building Code, Energy Conservation — and for contractors and designers working in the state, R405 is one of the most important sections to understand. It's the performance-based compliance path, and it's the option most custom homes and design-flexible projects end up using instead of the more rigid prescriptive route.
Florida's residential energy code offers multiple compliance approaches, but the two most commonly used are:
R402 (Prescriptive) — similar in concept to REScheck's prescriptive method, this path requires every envelope component (walls, ceiling, windows, etc.) to individually meet fixed minimum requirements for the applicable climate zone within Florida. It's straightforward but inflexible — no trade-offs allowed.
R405 (Performance) — this path uses whole-house energy simulation software to demonstrate that a proposed home's total annual energy performance meets or exceeds a code-defined baseline "reference home" with the same geometry but built to prescriptive minimums. Because it's based on total performance rather than component-by-component minimums, R405 gives designers much more flexibility — a larger window package, an unconventional layout, or non-standard assemblies can all still comply as long as the overall energy performance measures up.
R405 compliance is determined by running an approved energy simulation program that models the proposed home's actual specifications — envelope assemblies, HVAC equipment efficiency, duct location and leakage, water heating system, and other energy-relevant details — against a reference home baseline. The proposed home's estimated energy use has to be at or below the reference home's, factoring in required credits and specific mandatory requirements that apply regardless of which path is used.
The output is a compliance report (the R405 form) showing the comparison, the inputs used, and confirmation that the project meets the total energy performance requirement. This is the documentation submitted with the building permit application.
The 9th Edition (2026) Florida Building Code, Energy Conservation is based on the 8th Edition (2023), incorporating updates from the 2024 IECC along with Florida Building Commission approved modifications — meaning the specific credits, baseline assumptions, and mandatory requirements referenced in R405 do get updated with each code cycle, and staying current on the applicable edition for a given project matters.
For projects with larger window-to-wall ratios, open floor plans with extensive glazing, or unconventional envelope designs, the R402 prescriptive path can be genuinely difficult or impossible to meet on individual components. R405's whole-house approach lets those design choices get offset by improvements elsewhere — better HVAC efficiency, tighter duct sealing, improved water heating — without forcing a redesign of the envelope itself.
One documentation detail that trips up a lot of first-time R405 submissions: if the compliance form doesn't indicate "default leakage" assumptions, a completed duct leakage test report is required as part of the performance method documentation. This means duct leakage testing (typically performed once ductwork is installed but before drywall, or as a final test) needs to be planned into the project schedule, not treated as an afterthought — a home that was modeled assuming tested (verified low) duct leakage but never actually gets tested creates a documentation gap that can hold up final inspection.
Even under the performance method, certain requirements are mandatory and can't be traded off through energy modeling — things like minimum equipment efficiency thresholds, specific insulation requirements in certain assemblies, and air sealing requirements. R405 gives flexibility on the overall performance target, not a blanket exemption from every individual code requirement.
For simple, conventional home designs that comfortably meet prescriptive minimums on every component, R402 can be the faster, simpler path — no energy modeling software required, just a component checklist. For anything with more design ambition — larger glazing areas, complex geometry, or a desire to offset one weaker assembly with strength elsewhere — R405 is usually the more practical route, even though it requires approved simulation software and more detailed input data.
R402 prescriptive compliance requires every envelope component to independently meet a fixed minimum, with no ability to compensate for one component falling short with strength elsewhere. Custom homes frequently include design elements — expansive glazing for water or golf course views, vaulted ceilings with unconventional insulation cavities, unique architectural massing — that don't align cleanly with prescriptive assumptions built around more standard construction.
Because R405 modeling can inform design decisions before they're finalized, custom home projects benefit from running preliminary compliance models early in the design process — while window placement, glazing selection, and mechanical system specifications are still flexible — rather than waiting until construction documents are complete to discover a compliance gap that requires late-stage redesign.
Custom home clients often have strong aesthetic priorities — specific window styles, particular architectural features — that aren't always the most energy-efficient options available. R405 modeling helps identify where compliance can be achieved by strengthening other parts of the design (mechanical efficiency, duct performance, additional insulation) rather than compromising the aesthetic choices driving the project.
Custom home R405 submittals often involve more design iteration than standard production homes, which means the compliance model may need to be rerun multiple times as specifications evolve. Keeping the model updated alongside design changes — rather than relying on an early-stage model that no longer reflects the final specified materials — is particularly important on custom projects where late design changes are common.
Is R405 more expensive or time-consuming than the prescriptive path?
It typically requires more detailed data collection and approved simulation software, so it can take more upfront work, but it often saves money and design flexibility overall by avoiding costly envelope redesigns to meet prescriptive minimums.
Does R405 replace the need for a Manual J load calculation?
No — R405 is an energy code compliance demonstration, not an HVAC load calculation. Manual J is still required separately for correct equipment sizing.
What happens if duct leakage testing isn't completed after an R405 submission assumed tested leakage?
This creates a documentation mismatch that can delay final inspection approval — the as-built performance needs to match what was submitted and modeled.
Do R405 requirements change with each Florida Building Code cycle?
Yes — each edition (roughly every three years, with interim updates) can adjust reference home assumptions, credits, and mandatory requirements, so confirming the current applicable edition for a project's permit date matters.
Is R405 required for custom homes, or just commonly used?
It's not required specifically for custom homes — builders can choose either R402 or R405 for any residential project — but R405's trade-off flexibility makes it a more practical fit for designs that don't meet prescriptive minimums.
How early in design should R405 modeling begin on a custom home?
As early as feasible, ideally once major design elements like glazing area and mechanical system type are being considered, so compliance can inform design decisions rather than constrain them after the fact.
Does a custom home's R405 model need to be updated if materials change during construction?
Yes — any change to specified materials that were part of the original model should be reflected in an updated compliance calculation to ensure the as-built home matches what was actually modeled and permitted.
Psychro.Pro supports Florida R405 performance path documentation alongside Manual J, S, and D — keeping your energy code compliance and HVAC sizing aligned on the same project data. See our Florida R405 reports.